Fuel Storage Tank Systems
Fully integrated fuel storage tank systems for mining, port, industrial, and power generation facilities — designed, fabricated, and commissioned under a single EPC responsibility.
OEM Fuel Storage Tank Systems
Rexline Engineering Indonesia is an EPC and OEM manufacturing specialist delivering fully integrated fuel storage tank systems for mining, port, industrial, and power generation facilities across Indonesia.
Rexline designs, fabricates, installs, and commissions 500 KL, 750 KL, and 1000 KL fuel storage tanks — complete with pumping stations, transfer pipelines, truck loading systems, fire protection systems, PLC/SCADA automation, and full Civil–Mechanical–Electrical–Instrumentation–Fire & Safety (CMEIF) scope under a single EPC responsibility.
Our solutions are engineered for safe fuel handling, fire risk mitigation, operational reliability, regulatory compliance, and long-term asset performance — covering the full chain from jetty unloading to final truck dispensing.
A complete Rexline fuel storage facility typically includes:
- Fuel unloading from jetty / marine berth (SPM or fixed jetty)
- Pumping station and transfer pipelines
- Vertical fuel storage tanks (500 KL / 750 KL / 1000 KL)
- Bund walls and secondary containment
- Fire protection and emergency response systems
- Fuel circulation, filtration, and metering systems
- Truck loading and dispensing bays
- Central PLC and SCADA-based control room
Typical Tank Capacities
Rexline manufactures vertical cylindrical fuel storage tanks in accordance with applicable SNI, international codes, and client specifications.
Tank Design Features
All tanks are fabricated in Rexline's in-house facilities with full quality assurance and inspection.
- Carbon steel construction with corrosion allowance
- Fixed roof or cone roof configuration
- Internal and external fuel-grade coating systems
- Manholes, nozzles, vents, flame arrestors
- High-level and overfill protection
- Continuous level and temperature measurement
- Bund wall and secondary containment systems
- Jetty unloading pumps and manifolds
- Transfer pipelines (above ground / underground)
- Emergency shutdown valves (ESDV)
- Flow meters and custody transfer instrumentation
- Leak detection and pressure monitoring
- Pipe supports, sleepers, expansion loops
Key System Components
Every Rexline fuel storage facility is delivered as a complete integrated package — from pumping through to fire protection and automation.
- Duty / standby transfer pumps
- Booster pumps for truck loading
- Fuel filters and strainers
- Pressure relief and control systems
- Automatic valve actuation
- Drain, vent, and sampling systems
- Loading arms or hose reels
- Flow meters and batch controllers
- Automatic shut-off and interlocks
- Spill containment and drip trays
- Grounding and bonding systems
- Driver interface and authorization system
- Fixed foam fire suppression systems
- Foam pourers and foam chambers
- Fire water storage tanks
- Fire pumps — electric / diesel duty-standby
- Fire hydrant and hose reel systems
- Monitor nozzles for tank and bund protection
- Flame and gas detection systems
- Smoke and heat detectors
- Emergency shutdown (ESD) systems
- Overfill prevention and alarm systems
- Emergency stop stations
- Fire alarm and notification systems
- PLC control panels and MCCs
- SCADA system with graphical interface
- Tank level, temperature, and alarm management
- Pump sequencing and interlocks
- Emergency shutdown logic
- Data logging and reporting
- Tank foundations and ring beams
- Bund walls and containment slabs
- Pump house and control room buildings
- Pipe racks, sleepers, and trenches
- Roads, drainage, and hardstand areas
Fuel Storage Tanks in the Field
Fabricated and commissioned by Rexline across mining, port, and industrial facilities throughout Indonesia.
All tanks fabricated at Rexline's in-house facility · Lamongan, East Java, Indonesia
Replace with iframe embed code:
<iframe src="https://www.youtube.com/embed/VIDEO_ID"></iframe>
See the System in Operation
Watch Rexline's fuel storage systems — from tank fabrication at our Lamongan facility through to full site commissioning and operation.
- Tank fabrication and erection process walkthrough
- Pumping station and piping installation
- Fire protection and automation system integration
- Commissioning and truck loading system demonstration
Full EPC Scope
Rexline delivers complete end-to-end scope — from engineering design and OEM fabrication through to civil works, installation, and commissioning.
- Tank erection and mechanical installation
- Pump and equipment installation
- Piping fabrication and erection
- Valve installation and alignment
- Hydrostatic and pressure testing
- Power distribution and cabling
- MCCs and PLC panels
- Instrument installation and calibration
- Earthing and lightning protection
- Area and emergency lighting systems
- Process Flow Diagrams (PFDs)
- Piping & Instrumentation Diagrams (P&IDs)
- General Arrangement (GA) drawings
- Civil and structural calculations
- Electrical single-line diagrams
- PLC/SCADA architecture and logic
- Fire and safety philosophy
Where We Deliver
Rexline fuel storage systems are proven across Indonesia's most demanding industrial and mining environments.
Applicable SNI Standards
Rexline Engineering Indonesia designs and executes fuel storage systems in compliance with all applicable Indonesian National Standards (SNI) and relevant international engineering codes — covering structural, fire, piping, welding, electrical, and instrumentation works.
Compliance is verified through documented inspection records, material certificates, and third-party testing where required by the project specification.
The Rexline Advantage
Six reasons why mining operators, port authorities, and industrial clients choose Rexline for their fuel storage systems.
Commissioning & Handover
Rexline's commitment extends through to final handover — ensuring every system is fully tested, documented, and handed over with complete operator training and as-built records.
Committed to delivering safe, fully automated, and regulation-compliant fuel storage and handling facilities — engineered to protect people, assets, and operations while ensuring efficient and reliable fuel supply.